Volume Correction
Volume Correctors represent an essential part of any Gas Measurement System. As gas is used and flows through the pipes, the volume of the gas is affected by the temperature and pressure of the system, this can make it difficult to accurately track gas usage.
The Elgas Range of Volume Correctors can take these differences in temperature and pressure into account and give you an accurate representation of your gas usage.
These devices are MID certified and due to the number of communication methods available they can be used with existing SCADA systems or can be set up to be read remotely
Gas volume correctors represent an essential part of any Gas Measurement System. As gas is used and flows through your network, the volume of the gas is affected by the temperature and pressure of this system, this can make it difficult to accurately track and measure gas usage.
Incorrect measuring can lead to an overconsumption of gas or inaccurate pressure readings leading to failures in your network. Correctors take the difference in temperature and pressure into account and provide you with a more accurate representation of your gas usage.
This, in turn, saves you on costs, maintenance fees and time.
Gas Volume corrector services
The Gas detectors supplied by Vermac are MID certified and due to the number of communication methods available they can be used with existing SCADA systems or can be set up to be read remotely.
Vermac can provide you with gas volume correctors devices, installation technicians and training on how to accurately read and understand the information being obtained by your gas correctors.
What are Gas correctors and why do you need them?
Designed to work across various industries, gas volume correctors allow for accurate measurement and reading of gas in large volumes. Gas volume corrector devices convert your flow rate of gas into a standard state for proper recording.
Gas volume correctors work most accurately when used in conjunction with other gas network devices such as gas meters and filter systems. Used in tandem they give the most accurate reading and for many industries, it is essential to install gas volume corrector devices along with other devices.
Gas volume corrector mounts and placing
Gas volume correctors are available in various mount options allowing for better placement and concealment across work floors.
Meter mounts, wall mounts and pipe stand mounts are the most common mounting options. Vermac can supply and install gas volume correctors on any network safely and securely.
Modern gas volume correctors are most often installed and configured with laptops and other smart devices. This provides technicians with the ability to record, analyse and adjust when necessary. Software used in tandem with these durable devices allows normal operation procedures to continue.
One of the key benefits of modern digitized volume corrector’s is the ability of technicians to monitor each device from a remote location.
Well-equipped command centres away from work floors free up space, increase safety and allowing for constant monitoring controls. This is ideal for large manufacturing plants.
Used in conjunction with a gas meter, accurate gas volume correction can be maintained along critical points of your system. Vermac supply sturdy industry standard and certified correctors to clients across Ireland.
Gas volume correctors and flow rate
Correctors maintain and ensure the constant flow of gas throughout your network, reducing any hindrance to flow and work rate. Accurate detection provided by correctors considers temperature and pressure within your system, in conjunction with readings from your gas meter device.
These readings provide operators with more insight into gas usage and requirements across your system. Correctors will also help highlight leaks and errors along with your system.
If your business goals are safety, cost-saving, environmental and economic achievements then you need the best correctors on the market, something we provide here at Vermac.
Gas Meter vs Volume corrector?
Gas volume correctors
Calculate summarise and determine increments of gas volume measured by gas meters along your system at base conditions. To do this it determines measures such as temperature and pressure within your system for wholesale gas use.
Correctors may also consider factors such as external temperature.
Gas Meters
Measure a defined volume of gas regardless of factors such as temperature and pressure. Our devices consist of turbine, axial and rotary meters.
These devices along with all Vermac products can determine natural gas usage, LPG and other heavy industry gases. These products can be used in industries including:
- Milk Processing (Whey-Casein)
- Cheesemaking
- Meat processing
- Powder coating
- Product finishing
- Plastic rotational moulding
- Crop Drying
- Paint Curing
- Brewing
- CHP applications
- Ceramics
- Packaging
- Air heating
- Drying Ovens
Corrector models
All our correctors are supplied by Elcor. The Elcor volume corrector is designed to be a compact, versatile device integrating metrological measurement, telemetry and communications capabilities.
This gives operators a full spectrum of information and reporting data.
Housed in an IP66 rated Glass fiber Polycarbonate case with a lockable closing mechanism these devices are tamper and weather resistant.
Vermac Gas Services
Vermac has worked in the gas industry for over 20 years. Our product range includes burners, gas meters, gas detection systems and Gas filters. We only partner with trusted manufacturers to provide our clients with the latest and best tool for natural gas operations and other heavy gas usage industries.
We also conduct maintenance, replacement and servicing operations to clients throughout Ireland ensuring the equipment they use is calibrated and working correctly. We do this to reduce costs, improve energy ratings and gas use efficiency.
For any equipment, maintenance or servicing needs get in touch with Vermac today and we can assist you and your business in safety, regulations and quality network operations.
Showing all 7 results